05 Eylül 2009

BW RSAR8 Error

ile Yunus KALDIRIM

BW’da alınan RSAR8 hatası ile ilgili çözümdür. Upgrade sonrası sistem adlarını eşlemede kontrol yapıldığında veya aktifleştirilmeye çalışıldığında alınan bir dizi hatanın başlangıcıdır.

Problem:

This is the Error Message we are facing

BI unknown in source system RSAR 8
BI IDoc type ZSCB014 is not the same as source system IDoc type RSAR 371
The following errors occurred in the source system: RSAR 374
Incorrect IDoc type ZSCC502 in the ALE definition of the source system RSAR 373
Result of the destination check: Error during the retrieval of the logon data store d in secure storage RSAR 375
Source system release 700 is not the same as local information 46C RSAR 671

Kindly suggest how to rectify this issue and what could be the root cause.

Solution:

Restore your source system connection it will update all enrtries in r/3 system.

rsa1……….>source system menu………..>right click on source system……..> restore

make sure if have Password for background user ALEREMOTE or BWREMOTE

  • Bu işlem genellikle partner tanımlaması ile karıştırılır.O tarafta uyarlama ile boşuna uğraşılabilir. Halbuki Rsa1’deki kaynak sistemlerden ilgili sistem üzerinde geri yükle ile düzeltilmektedir.